first previous next last contents

Primer3

The Primer3 Module allows the selection of primer candidates for targets sequences, for example microsatellites. These targets could be annotated regions in the Gap4 database or stored in a table of a SQLite database. The image below shows the interface of the Primer3 Module. The different components of the interface are marked with red numbers in this image. The function of these components will be explained in the following.
1. The contig input The sequences from the Gap4 database for the primer search can here be selected. The standard selection is “all contigs”, this means the whole database. Under “file” a file could be loaded which has to contain a list of contigs from the database. After clicking the “Browse”-button when the option “list” is selected a window with a list of different options will open. It can be chosen between “all contigs”, “all readings”, “contigs” and “readings”. 2. Target- and excluded-regions “Select Tagname for Target” sets a tag name which refers to the targets regions. The “Excluded Regions” text field should contain all tag names of marked regions were no primers should be placed, for example all repeat tag names (these are already set there as standard). 3. Setting of target parameters The option “Choose min. Gap between Targets” has a default value of 25, this stands for the distance in bases which shall be between two targets. If two targets have less then this 25 bases between each other they will be counted as one. The default minimum length of a target is 6, only targets as long as the min. length or longer will be used for primer search. The “Checkbox” with the option “Only single SSR” allow you only to search for targets of a single SSRmotif. (For example: if an AC-SSR lies next to AT-SSR it will be handled like one SSR and one target, if the “Only single SSR”-option is not selected. If the option is selected these SSRs won’t be counted as targets, because there is no room for a primer to be placed between them and the option will not allow two repeats in one primer product) 4. The primer parameters Here some parameters can be set: the length of the primer in bases, the GC content, the melting temperature of the primer (“TM”) and the melting temperature of the product (“Product TM”). Additional the "Poly X"-value, which sets the maximal occurance of the same base in a row, and the "Product Size List", where it is possible to set different size spans for the products. More than one size range can be set, example: "100-150 200-300". 5. Primer- and Sequence-Quality If the “Primer- and Sequence-Quality”-checkbox is selected only sequences with quality values in between the “Minimal-Range-Quality” and the “Maximal-Range-Quality” are used for the primer search. Also every base of a primer location needs a minimal quality value like the one set at “Minimal-Primer-Quality”, otherwise the primer will not be created at this sequence position. 6. Primer3 input and output files It can be chosen if the primer3 input and output text files should be kept or not, the default option is “No”. 7. Primer passed files The „Primer3_primer.passed“-file contains a list of contigs which include primer for targets. The „Primer3_no_primer.passed“-file contains a list of contigs which does not include primers. By loading the „Primer3_no_primer.passed“-file (see Point 1) a more specific primer search could be run, which will be concentrated on contigs without useful primer locations. 8. Extended Options Displays Parameter-Box under point 10. 9. The Buttons By clicking the “OK”-button Primer3 will be executed and a window opens which contains a table with possible primer candidates. The “Help”-button opens a HTML-page with the information needed to handle the Primer3 interface. The “Safe”-button stores the interface parameters in the file “primer3_par.txt”, it can be found in “{STADENROOT}\lib\stamp\”. 10.Extended primer parameters "Num. of Results" set the number of returned primer pairs. "Max. Tm Difference" is the maximal allowed difference of the forward and reverse primer Tm. "Salt conc. (mM) in PCR" refers to the salt concentration (milli molar) of the PCR-mix and influences the calculation of the melting temperature. "Primer conc. (nM) in PCR" refers to the concentration of primers (nano molar) in the PCR-mix. "Max. Complementary" sets the maximal allowed alignment score for self alignment. "Max. 3' Complementary" the same for 3'end. "Num of allowed Ns" stands for the number of unrecognized bases in a primer, like "N", "-" or "*".

[picture]

The Primer Table allows a manual selection of primers for export to a tab-delimited text file or to the Gap4/SQLite database.

[picture] 1. A table of the suggested primers, a double click on a row opens a contig editor (See 3.2.The Contig Editor). 2. The buttons to select or deselect all primers in the list, with the button “Standard Selection” the originally selection will be recreated. 3. Here the names of the export file, SQLite database and Gap4 database annotation are set. 4. The comment set in this text field will be used for identification in the SQLite database. 5. The “Add to…”-button write all selected rows to either the Gap4 database or the experiment files, this depends on status of the checkboxes “DB” and “exp-File”. 6. Exports all selected rows to a text file (“Export to File”) or to a SQLite database (“Export to SQLite Database”). 7. The button “Create Multiplex” opens the interface of the Multiplex Module and uses all selected rows in the primer table for the creation of the multiplex. A second use of the “Create Multiplex”-option will destroy the multiplex table window and create a new one, so the multiplex information from the first run should be stored before starting a second run. 8. This text field shows additional primer information like the GC-content of the primer pair and the melting temperature of the primer product.

first previous next last contents

URL: http://staden.sourceforge.net/manual/gap4_windows_primer3.html