The Multiplex Module allows the selection of primer candidates, which will not interact with each other and so could be used in a Multiplex PCR.The image below shows the interface of the Multiplex Module. The different components of the interface are marked with red numbers in this image. The function of these components will be explained in the following. 1. Primer for Multiplex In this component of the interface, the source of the primer information for the multiplex has to be set. If the option “Use Primer file” is set to “No” only the primers already written to the Gap4 database, with the tags set in “Primer Tags from DB”, will be used. Otherwise a file with primer information will be loaded. This should be a file created with the Primer3 Module (the “Experiments”-option: “Create flanking Primer”). Next there is a “Check against sequences”-checkbox. Only if this box is selected the interface part “Sequences for Multiplex” will be used. 2. Sequences for Multiplex If the checkbox “Sequences for Multiplex” in Part 1 was selected the primers for the multiplex will be blasted against the sequences in the Gap4 database. As an alternative it is possible to load a fasta file of sequences to blast against. If the checkbox “Show Primertable for selection” is checked and the “OK”-Button in Part 5 is clicked a table will open, which allows a manual selection of the primer by means of the blast results for the creation of the multiplex (see also “3.2. The Blast-result table”). 3. Primer Parameters Here will be set some parameters for the multiplex creation. The “Number of Multiplex Tables” sets the number of different multiplexes which will be created, with an increasing number the time for the calculation will also increase. The “Max. Alignment Score” sets the maximal allowed number of matches between two primers to be included in one multiplex. The “Max. Penalty” relates to the penalty value in the primer information, if a primer penalty higher than the set value the primer will not be used for the creation of a multiplex. 4. R-Tree This component is only of interest, if the program “R” (http://www.r-project.org) is installed. The button “Configure R-Parameters” opens a window with the R-Parameters (For more information see the next page "R-Tree"). After clicking the button “Create R-Tree of Primerlist” a PNG image of a likelihood tree of the primer for the multiplex creation will be created an opened. The PNG will be created in the same folder as the currently opened Gap4 database. 5. The Buttons “OK” will open a blast-result table or the multiplex table, depending on the selection of the checkbox “Show Primertable for selection” in Part 2. “Help” opens a HTML-page with all information to the Multiplex Module. The “Safe”-button stores the interface parameters in the file “multiplex_par.txt”, it can be found in “{STADENROOT}\lib\stamp\”.
The Blast-result Table allows a manual selection of primers as basis for the multiplex creation process.
1. A table with all primers from the primer file or the Gap4 database. Some primers are already selected on basis of the blast results. Whether a primer is selected or not depends only on the number of matches with the sequences of the Gap4 database or the loaded sequence file. Often the assembly of the Gap4 database is insufficient and the same sequence appears as a number of different contigs. In this case a primer could produce a number of hits, but actually has only a single binding place. Because of this, a manual selection or review is advisable. By a double click on a data row a contig editor will open, in which the primer product will be highlighted in the consensus. 2. Displays a table of all binding places of the selected primer pair. The first column of the table holds the information which of the two primers in a pair has a blast hit at the specific position; “Forward” refers to the forward primer of the selected pair and “Reverse” to the corresponding reverse primer. The column “Score” shows the number of alignment matches for the blast hit. This means a score of 20 equals 20 bases of the primer which could anneal at this position of the sequence. With a double click on a row in the table a contig editor will open, with a highlighted part in the consensus sequence. 3. The button “Create Multiplex”, which does exactly that, will open a new window with a table of proposed primer pairs to be used in a multiplex experimentally. 4. Shows the primer parameter earlier already set, here it is possible to change them again. The Multiplex Table displays all primer pairs useable in a single multiplex PCR experiment.
1. A primer table like the one in the blast-result table, but here only the compatible primer pairs are displayed. 2. The buttons under here enable to select/deselect all primers in the list. 3. Here the names of the export file, SQLite database and Gap4 database annotation are set. 4. The text field where a comment can be written, this comment allows for an easy identification of this table when written to the SQLite database and later reopened. 5. Here the names of the export file, SQLite database and Gap4 database annotation are set. 6. With the button “Safe Change” the comment for the table can be changed. The actual comment will be used if the table is again exported to a SQLite database. 7. These two buttons, “Previous Multiplex” and “Next Multiplex”, enable to go through the different multiplex tables which where created. The number of available tables depends of the number set at the parameter “Number of Tables”.